Quiet, powerful blowers for paths, parks and public spaces
Choose a pedestrian, ride-on mower or tractor-mounted Kersten LBV blower to move wet leaves, grass clippings and light debris quickly while keeping noise and carrier weight under control.
- Pedestrian and vehicle-mounted options
- Air output from 85 to 140 m³/min
- Discharge range up to approximately 12 m
- Noise-reduced turbine and housing
Five blower configurations for pedestrian units, mowers and tractors
Start with the carrier and drive system. The model cards then show the output, mounting interface and the features that distinguish each configuration.
Pedestrian - UBS 9, 13 and 16
LBV 5100 M-ABF
Compact pedestrian clearance with a fixed outlet and 90-degree adaptor. The PE turbine housing can be rotated to set the outlet position, while the silencer and balanced aluminium fan keep the unit light and controlled.
- 85 m³/minAir output
- Approx. 8 mDischarge range
- 81 kgMachine weight
- MechanicalAttachment drive
Pedestrian - UBS Hydro 16
LBV 6900 M-ABF
The higher-output UBS Hydro 16 option, retaining the fixed outlet and 90-degree adaptor while increasing air performance and working range for wetter, heavier seasonal material.
- 115 m³/minAir output
- Approx. 12 mDischarge range
- 85 kgMachine weight
- MechanicalAttachment drive
Ride-on mower attachment
LBV-HO-FKDR
A self-powered front-mounted blower with an 11.7 hp Honda industrial engine, automatic oil shut-off, right-hand discharge, adjustable scoop, height-adjustable wheels and integrated parking supports.
- 90 m³/minAir output
- Approx. 8 mDischarge range
- 91 kgMachine weight
- 11.7 hpHonda engine
Tractor and municipal carrier
LBV 6900 M-ABR
A 140 m³/min PTO-driven blower with cardan shaft included, 230 km/h air velocity, a standard right-hand discharge and optional 360-degree outlet control for suitable installations.
- 140 m³/minTheoretical output
- Approx. 12 mDischarge range
- 85 kgMachine weight
- PTOMechanical drive
Hydraulic tractor or implement carrier
LBV 6900 H-ABR
The 40 L/min hydraulic-drive version for carriers without a suitable PTO, delivering the same high-output fan package and supporting optional in-cab 360-degree outlet control.
- 140 m³/minTheoretical output
- Approx. 12 mDischarge range
- 85 kgMachine weight
- 40 L/minRecommended oil flow
The practical difference between the five configurations
This table avoids repeating the output figures shown on the product cards and focuses on what the carrier must provide and how the air is directed.
| Model | Carrier provides | Standard outlet arrangement | What makes it different |
|---|---|---|---|
| LBV 5100 M-ABF | UBS Hydro 9, 13 or 16 and ABF mounting flange | Fixed outlet with 90-degree adaptor; housing position can be adjusted | Smallest and lightest pedestrian option at 81 kg |
| LBV 6900 M-ABF | UBS Hydro 16 and ABF mounting flange | Fixed outlet with 90-degree adaptor | Higher-output pedestrian package for heavier leaf fall |
| LBV-HO-FKDR | Compatible FKDR front linkage; blower has its own engine | Right-hand discharge with adjustable scoop | 11.7 hp Honda engine, automatic oil shut-off and parking supports |
| LBV 6900 M-ABR | Correct PTO and vehicle-specific ABR-LBV bracket | Right-hand discharge with adjustable scoop | PTO drive, cardan shaft included and no hydraulic fan-drive demand |
| LBV 6900 H-ABR | 40 L/min recommended hydraulic service and ABR-LBV bracket | Right-hand discharge with adjustable scoop | High-output fan drive for carriers without a suitable PTO |
Choose how the blower is powered and how the chute is controlled
The blower drive and the outlet-control drive are separate decisions. A mechanically driven blower can still use an electric or hydraulic directional chute when the carrier and installation support it.
Mechanical PTO fan drive
The LBV 6900 M-ABR takes its fan drive from the carrier PTO. It delivers up to 140 m³/min theoretical air output and up to 230 km/h air velocity without using the carrier hydraulics to power the fan.
- Cardan shaft included with the blower
- Confirm PTO position, speed, direction and shaft geometry
- Vehicle-specific ABR-LBV mounting bracket required
Hydraulic fan drive
The LBV 6900 H-ABR uses the carrier hydraulic circuit instead of a PTO. It shares the 6900 fan, housing and output package, with 40 L/min listed as the recommended oil flow.
- No separate engine or mechanical PTO fan drive
- Confirm continuous flow, pressure, return and cooling
- Vehicle-specific ABR-LBV mounting bracket required
Electric 360-degree chute
The optional electric nozzle uses a turntable to provide stepless 360-degree adjustment. It is a useful route where electric outlet control is preferred instead of using an additional hydraulic service.
- Electric drive for the directional nozzle
- Stepless 360-degree rotation
- Confirm the carrier electrical supply and control installation
Hydraulic 360-degree chute
The hydraulic directional nozzle gives stepless 360-degree outlet rotation from the cab, allowing the operator to redirect the air stream without stopping to reposition the standard scoop.
- In-cab directional control
- Double-acting spool valves required
- Confirm spare hydraulic services as well as blower fan flow
Noise and airflow management
PE turbine housings, inlet and outlet silencers and dynamically balanced aluminium fan wheels combine high airflow with specified sound levels below 84 dB on the LBV 6900 vehicle models.
Ground following and storage
Height-adjustable swivel wheels help the blower follow uneven ground, while stable support frames and parking supports simplify coupling, uncoupling and storage.
Interchangeable carrier mounting
ABF flanges, FKDR front linkages and vehicle-specific ABR frames match the blower to pedestrian units, ride-on mowers, compact tractors and municipal carriers.
Confirm the mounting and services before the blower is built for your carrier
Kersten UK checks the physical interface and available services together. This prevents a correct blower model being paired with the wrong bracket, PTO geometry, hydraulic circuit or outlet-control package.
- Mounting: carrier make and model, attachment point, linkage category, lift range and ground clearance.
- Fan drive: mechanical attachment drive, PTO details, self-powered engine or continuous hydraulic flow.
- Outlet control: standard scoop, electric 360-degree turntable or hydraulic 360-degree chute with double-acting spool service.
- Working environment: route width, discharge side, obstacles, public access and where the material must be windrowed or collected.
Find the best blower starting point for your carrier
Compare the models and outlet-control options above, then select your carrier and typical workload. The result narrows the choice before Kersten UK confirms the mounting and drive details.
Kersten Blower Finder
Choose the carrier and the work it needs to complete.
Watch the LBV clear leaves from a working surface
High air volume and a controlled outlet move leaf fall away from paths, edges and open areas so the material can be windrowed, collected or moved clear of the route.
Explore leaf and light debris managementBlow, sweep, vacuum or collect according to the site
Blowers are ideal for moving material out of corners and across open ground. Other Kersten systems can then collect or remove it where the job requires a complete clean-up.
Choosing and using a professional leaf blower
Which blower fits a Kersten UBS Hydro power unit?
The LBV 5100 M-ABF is listed for UBS Hydro 9, 13 and 16. The higher-output LBV 6900 M-ABF is listed for the UBS Hydro 16. Both require the correct ABF-LBV-KU 70 mounting flange.
Can a ride-on mower power the blower through its own PTO?
The LBV-HO-FKDR carries its own 11.7 hp Honda engine. The ride-on mower provides the carrier and compatible FKDR front linkage rather than the blower power.
What does the hydraulic LBV 6900 require?
The LBV 6900 H-ABR is listed with a recommended oil flow of 40 L/min. Flow, pressure, return arrangement, bracket and carrier cooling capacity should all be confirmed before supply.
Are Kersten blowers suitable for noise-sensitive sites?
The LBV design uses a noise-reduced turbine, PE housing and silencers. The LBV 5100 and 6900 models are specified below 84 dB, making them useful starting points for schools, parks and built-up areas where final operating controls are observed.
Can the discharge direction be changed?
Yes. The standard arrangements use a fixed outlet or adjustable scoop. Suitable LBV 6900 ABR installations can use a stepless 360-degree electric turntable or a hydraulic in-cab chute; the hydraulic option requires double-acting spool valves, while the electrical connection for the electric option must be confirmed for the carrier.
Should leaves be blown or collected?
Blowing is effective for moving material out of edges, around obstacles and into a windrow. Where the site requires complete removal, pair the blower with a sweeper, collector or vacuum system.
Confirm your blower fitment with Kersten UK
Send the carrier make, model, drive details and preferred outlet control. The team will identify the blower, bracket and installation requirements for a verified quotation.